MIL-DTL-44427A
TABLE II. End item visual defects (continued)
Classification
Examine
Defect
Major
Minor
A
B
General
Any other construction detail not performed
as specified
129
Marking &
labels
Omitted, incorrect, illegible, or misplaced:
- erection or maintenance instructions
212
- identification
325
Cleanness
Grease or oil stains
326
Thread ends not trimmed to ½ inch or less
(except in slide fastener area)
327
Thread ends not trimmed to ½ inch or less
in slide fastener area
213
4.4.4 End item dimensional examination. The end item shall be examined for the defects
listed in Table II. Only those dimensions that can be evaluated without damaging or
disassembling the end items shall be examined. The lot size shall be expressed in units of tents.
covers or frame carrying covers, as applicable. The sample unit shall be one end section,
intermediate section, tent cover or frame carrying cover, as applicable. The inspection level shall
be S-3.
TABLE III. End item dimensional defects
Classification
Examine
Defect
Major
Minor
Overall
Larger or smaller than specified
dimensions of (including applicable tolerances)
101
tent, fly
and liner
Dimensions, Larger or smaller than specified
other than
(including applicable tolerances)
overall on tent
- affecting serviceability
102
fly & liner
- not affecting serviceability
201
4.4.5 End item performance testing. Tents shall be tested as specified in 4.5.1 and 4.5.2
for compliance with the requirements of 3.3.3, 3.3.3.1 and 3.7. The lot size shall be expressed in
units of tent bodies. The sample unit shall be one completely fabricated tent body. The inspection
level shall be S-3. The lot shall be rejected if one or more sample units fail to meet the
requirement.
*4.4.6 Packaging examination. The fully packaged end items shall be examined for
marking, materials, workmanship and content defects.
4.5 Methods of inspection.
9