MIL-DTL-3372G
Table I. End item visual examination.
Classification
Examine
Defect
Major
Minor
A
B
Hardware
-fails to perform intended function
104
(cont'd)
-will perform intended function
205
Corroded area
303
Burr or sharp edges which may cause
injury in handling or damage to fabric
105
End clips
Webbing not flat at point of
entrance into clip
304
Clinched tight, cutting webbing
106
Seams and
Open seam on stitch type 301:
stitching
-for more than 1 inch
107
-for more than ½ inch
but not more than 1 inch
206
-for more than ¼ inch but
not more than ½ inch
305
NOTE: A seam shall be classified as open
when one or more stitches joining a
seam are broken, or when one or more
skipped or runoff, stitches occur.
On double stitched seams, a seam
shall be classified as open when
either one or both sides of a seam are open.
Raw edges caught in stitching
(except end of inside binding):
-more than 1 inch
207
-more than ½ inch but not
more than 1 inch
306
Thread breaks:
-overstitched less than 1 inch
on stitch type 301
307
-overstitched less than ¾ inch
on stitch type 304
308
NOTE: Thread breaks not overstitched shall
be classified as open seams.
Needle chew resulting in hole,
cut or tear
108
Skipped stitches overstitched less
than 1 inch on stitch type 301,
304, 503, 504, or 505 when 2 or
7