MIL-DTL-10035L
4.3.2 In-process inspection. Inspection shall be made of the following operations or assemblies to
establish conformance to specified requirements. Whenever nonconformance is noted, correction shall
be made to the items affected and to the operation. Items which cannot be corrected shall be removed
from production. The inspection level shall be S-1.
a. Holes punched to receive grommets are in compliance with 3.3.3.
b. There shall be no lubrication of polyester thread prior to or during sewing operations in
compliance with 3.3.1.8.
c. Holes punched to receive male or female parts of snap fasteners are in compliance with
3.3.4.
4.3.3 End item visual examination.
4.3.3.1 Tent with liner and cover. The end item shall be in an erected position so that both the inside
and outside of the tent can be examined, along with its cover and liner, for defects listed in table II. The
lot size shall be expressed in units of tents with liners and covers. The sample unit shall be one tent with
liner and cover. The inspection level shall be I.
4.3.3.2 Tent liner, only. The end item shall be examined for the applicable defects listed in table II.
The lot size shall be expressed in units of liners. The sample unit shall be one liner and the inspection
level shall be I.
4.3.3.3 Tent cover, only. The end item shall be examined for the applicable defects listed in table II.
The lot size shall be expressed in units of covers. The sample unit shall be one cover. The inspection
level shall be I.
TABLE II. End item visual defects
Classification
Examine
Defect
Major Minor
A
B
Fabric
Cut, tear, or hole (including exposed
drill hole) greater than 1/8 inch in
length or diameter:
- on tent
101
- on cover or snow cloth
201
Cut , tear, or hole (including exposed
drill hole) 1/8 inch or less in length
or diameter:
- more than 20:
- on tent
102
- on cover or snow cloth
202
- more than 10 but not more than 20:
- on tent
203
- on cover or snow cloth
301
- more than 5 but not more than 10:
- on tent
302
Fabric, liner
Cut, tear, hole (including exposed
drill hole):
- greater than ¼ inch in length
or diameter on liner
103