MIL-DTL-10035L
TABLE II. End item visual defects (cont'd)
Classification
Examine
Defect
Major Minor
A
B
General
Any other construction detail not
performed as specified
237
Labels
Omitted, incorrect, illegible, or
misplaced:
- erection instructions
238
- identification
338
Marking "US" and
Omitted, incorrect, illegible, or
Identification
misplaced
339
Cleanliness
Grease or oil stains
340
Thread ends not trimmed to ¼ inch
or less (except in slide fastener area)
341
Thread ends not trimmed to ¼ inch
or less in slide fastener area
239
4.4.4 End item dimension examination.
* 4.4.4.1 Tent with liner and cover. The end item shall be examined for the defects listed in table III.
The lot size shall be expressed in units of tents with liners and covers. The sample unit shall unit be one
tent with liner and cover. The inspection level shall be S-2.
* 4.4.4.2 Tent liner, only. The end item shall be examined for the applicable defects listed in table III.
The lot size shall be expressed in units of liners. The sample unit shall be one liner. The inspection level
shall be S-2.
* 4.4.4.3 Tent cover, only. The end item shall be examined for the applicable defects listed listed in
table III. The lot size shall be expressed in units of covers. The sample unit shall be one cover. The
inspection level shall be S-2.
TABLE III. End item dimensional defects
Classification
Examine
Defect
Major Minor
A
B
Overall dimensions
Tent and liner
Smaller than specified dimensions
less applicable minus tolerance
101
Larger than specified dimensions
and applicable plus tolerance
indicated on drawings
301
Cover
Smaller than specified dimensions less
applicable minus tolerance indicated
20