MIL-DTL-12354G
4.4.4 End item dimension examination.
*4.4.4.1 Tent with cover. The end item shall be in erected position so that both the inside and outside of the tent
can be examined, along with its cover, for defects listed in table III. The lot size shall be expressed in units of
tents with covers. The sample unit shall be one tent with its cover. The inspection level shall be S-3. arctic
*4.4.4.2 Cover only. The end item shall be in a position so that both the inside and outside of the cover can be
examined for the applicable defects listed in table III. The lot size shall be expressed in units of covers. The
sample unit shall be one cover. The inspection level shall be S-3.
TABLE III. End item dimensional defects
Classification
Examine
Defect
Major Minor
A
B
Overall dimensions
Smaller than specified dimensions
of tent
less applicable minus tolerance
indicated on drawing
101
Larger than specified dimensions
and applicable plus tolerance
indicated on drawings
301
Dimensions: tent
Smaller than specified dimensions
cover; ventilator
less applicable minus tolerance
opening
indicated on drawings, but not smaller
than the specified dimensions less twice
the applicable minus tolerance
302
Smaller than specified dimensions less
twice the applicable minus tolerance
indicated on drawing
201
Larger than specified dimensions and
applicable plus tolerance indicated
on drawings
303
Location dimensions
Not within specified tolerance
202
(unless otherwise specified)
Webbing, tie tapes
Finished length less than specified by
more than 1 inch
304
Distance between splices on webbing
less than 5 feet
305
Grommets
Set beyond specified specified location by
more than 1/2 inch
306
23