TABLE II. End item visual defects (cont'd)
Classification
Examine
Defect
Major Minor
A
B
Construction
detail defects: (cont'd)
Tent line lugs
Any part of lug single ply
cont'd
construction
233
Piece "B" improperly set causing
fullness on tent or distortion of
corners
234
Doorway flaps
Turned-under edge of flap not
stitched through door opening tape
reinforcement
235
Top end of flap not stitched through
wall, eave band and tape reinforcement
236
Facing improperly applied, causing fullness
on flap
337
Toggles
Toggle held in place with single turn
of rope around groove or double turn not
overhand knotted
237
Toggle loops
Loops not securely stitched to flap
238
Ends of loops exposed, i.e. not turned
under or not caught in stitching
attaching flap to wall
338
Beckets
Cord not continuous
339
Any becket loose, i.e. not
caught in stitching on either side
239
Not continuous or spliced within
6 inches of grommet
340
Not spliced as specified
341
More than two splices per
connecting lug
240
Spliced cord less than 5 feet
in length
241
Splice not centered between beckets
342
Splices not made as indicated on
Drawing 5-4-285
242
Stovepipe shield
Set to roof with oval opening in a
horizontal position instead of vertical
126
Exposed stitching or needle holes
343