MIL-DTL-12354G
not be applied over seams or hardware areas. All other repairs required as a result of failure to meet the
requirements of the cup test and when authorized by the contracting officer shall be performed by treating with a
compound conforming to type I, class 1 of TT-P-595 prior to retesting (see 6.5.1).
3.3.13 Fusing of ends of synthetic webbing and tape. All ends of synthetic webbing, and tape shall be fused.
The apparatus used to fuse the ends shall be capable of providing sufficient heat to provide a smooth edge and
with the cut ends of the yarns all fused together. Fusing of the ends shall be accomplished prior to being
assembled for stitching.
3.3.14 Replacement of defective components. During the spreading, cutting and manufacturing process,
components of the tent having material defects or damages that are classified as defects in 4.3.2 or 4.3.3 shall
be removed from production and replaced with non-defective and properly matched components.
3.4 Marking. All marking and labels shall conform to DDD-L-20.
3.4.1 Special marking. The application of the letters "US" on the tent and cover, the instructions on the door,
the marking on the repair kit and the nomenclature on the cover shall conform to type IV, class 9 in the size
characters and in the locations shown on the drawings. Class 9 markings shall be clearly legible after subjection
to accelerated weathering.
3.4.2 Identification label. The identification labels shall be stitched to the tent and cover in the locations shown
on the drawings and shall conform to type VI, class 6 and shall be 3-1/2 inches by 5-1/2 inches minimum and a
blank space of at least 1-1/4 inches shall be provided on the bottom of the label for the Department of Defense
inspector's stamp.
3.4.3 Erection instruction label. Labels of erection instructions shall conform to type VI, class 7 and shall be
stitched to the tent and cover in the locations shown on the drawings. The label shall be a proportionate copy of
Drawing 5-4-544 as reproduced from a glossy print of this drawing furnished by the contracting officer. The
size of the label shall be, borderline to borderline, 15+1/4 inches in the longer dimension, with a minimum V2
inch margin outside of the borderline on all sides.
3.4.4 Care and maintenance instruction label. Labels of care and maintenance instructions shall conform to type
VI, class 7 and shall be stitched to the tent and cover in the locations shown on the drawings. The label shall be
a proportionate copy of Drawing 5-4-545, as reproduced from a glossy print of this drawing furnished by the
contracting officer. The size of the label shall be, borderline to borderline,
15+1/4 inches in the longer dimension, with a maximum 1/2 inch margin outside of the borderline on all sides.
12
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business