MIL-DTL-43695C
TABLE II. Classification of defects
Classification
Examine
Defect
Major
Minor
Any component split, punctured, fractured,
twisted, malformed, bent out of shape (except
end plate of header assembly, rivet and dowl pin)
110
End plate of header assembly is bent out of shape
to a degree that it will not function
111
End plate of header assembly is bent out of shape
but will function
208
Sharp edge or burr
209
Welding
Missing
112
Not sound, not smooth, not uniform or has
burn through area, pits, slag inclusion, porosity,
crack, fracture, flash or excess flux deposit
210
Riveting
Loose rivet
211
Set of rivet is such that the diagonal brace
(item 7-4) or shackle brace (item 7-7) is not
capable of being rotated by hand operation
113
Casting
Not clean or has pits, blowholes flashing and scale
212
Workman-
Split, puncture, fracture or bent out of shape
213
ship (rivet & Roll of a rivet contains more than one split
214
dowel pin)
Marking for Missing, illegible, incorrect or improper size
identification or location
215
Stitching
Not stitch type specified
216
Evidence of a thread break
217
------------------------------------------------------------------------------------------------------------------
1/ When the powder epoxy coating finishing method is used, it shall be tested in accordance with
ASTM-D-1005.
*4.4.4 End item dimensional examination. Examination shall be made of the end item for
compliance with the dimensions marked with an asterisk on the drawings. Any dimension not
within the specified tolerance shall be classified as a defect. The lot size shall be expressed in
units of frame sections of one type only. The sample unit shall be one frame section. The
inspection level shall be S-2.
*4.4.5 Examination of frame sections for defects during erection. The completely
fabricated frame sections shall be examined, during erection and striking, for the defects listed in
Table III. The lot size shall be expressed in units of frame sections of one type only. The sample
unit shall be one completely fabricated frame section. The inspection level shall be S-1.